Module now available Long-read sequencing analysis See the research

SaaS bioinformatics for infection intelligence

Introducing RipSeq

RipSeq sequence-based analysis reduces the time needed to identify infectious pathogens, in pure or poly-microbial samples, by up to 90%, and provides answers where other methods fail. Use any sequencing technology you want: Sanger and targeted NGS.

Workflow

Four steps. Under five minutes.

The total time for one analysis is less than five minutes, no matter if the sample is negative, pure or poly-microbial.

Upload your sequencing files

Sanger or targeted NGS, direct from specimen. Bulk upload is supported. Targeted NGS files are first processed locally, which reduces the information needed to upload by a factor of 1000:1, so there is no lengthy file upload and no costly big data file storage.

Platform agnostic

RipSeq analyzes both NGS and Sanger direct-from-specimen sequencing files, with a total analysis time of less than five minutes per sample.

Curated databases

RipSeq DB databases hold the most up-to-date references, without the clutter. Filtered and automatically curated to ensure an ID you can rely on.

Cloud SaaS solution

Always online and always updated. All you need is an internet browser. Reference databases are updated whenever major references are added or changed.

RipSeq NGS product sheet

NGSLong-read module

RipSeq NGS: impressive speed for targeted NGS

Using our novel algorithms, RipSeq will process your targeted NGS sequence file locally and reduce the information needed to upload by a factor of 1000:1, while still retaining resolution and specificity. This means no lengthy file upload, and no costly big data file storage.

After upload, the cloud-based RipSeq will analyze the uploaded reads against any of our curated RipSeq DB databases, no matter the target.

All of this completed in under five minutes, reporting included.

  • Rapid batch processing of NGS genomics data from clinical samples
  • Long-read sequencing analysis module now available
RipSeq Single product sheet

SingleSanger

RipSeq Single: one-click batch analysis

Our RipSeq Sanger products can handle it all, whether you have a pure sample or a more complex one. For pure samples, bulk analysis saves a lot of time: bulk upload, bulk analysis, automatic confidence status flags and automatic report generation.

  • One-click rapid batch analysis of DNA sequence files
  • Confidence status flags follow the CLSI clinical sequencing guidelines
  • No need to sift through hundreds of references in GenBank
RipSeq Mixed product sheet

MixedSanger

RipSeq Mixed: mono- and poly-microbial samples

RipSeq Mixed is an online software tool for rapid bacterial identification, with focus on analyzing mixed clinical samples. Through the use of advanced algorithms, it removes the need for manual isolation and re-cultivation of colonies from poly-microbial samples prior to 16S rDNA sequencing. This makes direct sequencing relevant for a broader range of clinical samples, including abscesses and pleural fluids.

RipSeq can also analyze samples you otherwise would have to discard, or at best culture and separate, not knowing if you missed anything.

RipSeq Mixed does not separate the traces. It makes all the possible combinations of reference sequences and matches each one against the mixed chromatogram.

>  One mixed chromatogram

Candidate reference sequences Six species, 15 possible combinations of two

Illustration with synthetic traces and six candidate species. Mixed peaks are written with IUPAC codes, for example R for A and G. Shaded positions are peaks the selected combination does not explain. Select any two species to try a combination yourself.

  • Reads and interprets mixed chromatograms containing up to three individual sequences
  • Automatically handles and identifies InDel copy variants in sequences from pure bacterial isolates

DB

RipSeq DB: the best microbial reference database there is

Pathogenomix's curated pathogen database, RipSeq DB, extends and improves the effectiveness of public DNA sequence databases such as GenBank and others. While GenBank contains large numbers of current references, it also has many uninformative or even erroneous references that hinder accurate identification. We even cross-reference all references with the latest taxonomy from NCBI and update the reference if needed.

To ensure the best reference quality and accuracy, RipSeq DB enables users to curate a more medically relevant reference database. Users can annotate, reject and approve references using personalized methods. This, on top of the solid foundation of advanced automatic filters and cross-referencing, makes RipSeq DB the database of choice.

Curated databases are a prerequisite for rapid, accurate analysis of targeted next generation sequencing (NGS) as well as Sanger data. They ensure that the user can be confident that the analysis results are complete and accurate.

  • Any target gene or region can be used for identification: 16S, ITS, rpoB and others

Try RipSeq

Start your 14-day free trial

RipSeq is always online and always updated. All you need is an internet browser.